Ford Escape: General Information / General Procedures - Wire Terminal Inspection and Removal
			
			Disconnect
 
 
 - 
  WARNING: 
 Before beginning any service procedure in this 
section, refer to Health and Safety Precautions in section 100-00 
General Information. Failure to follow this instruction may result in 
serious personal injury. WARNING: 
 Before beginning any service procedure in this 
section, refer to Health and Safety Precautions in section 100-00 
General Information. Failure to follow this instruction may result in 
serious personal injury.
 Refer to: Health and Safety Precautions (100-00 General Information, Description and Operation).
 
NOTE: 
 To avoid wiring pin (terminal) damage, Rotunda Flex Probes 
NUD105-R025D or Terminal Probe Kit 29-011A must be used to connect test 
equipment or jumper wires to pins (terminals).
 
 - 
 Male to female pin (terminal) fit is critical for correct connection and durability.
 
- 
 Pin (terminal) fit may be checked by using the 
mating pin (terminal) to test for normal separation force (a damaged pin
 or terminal will have very low separation force from the mating pin or 
terminal).
 
- 
 Correctly checking the separation force of small 
pins (terminals) may require removal of the connector terminal 
guide/retainer if it adds drag to the pin (terminal) insertion or 
removal.
 
- 
 For more detail on the replacement of damaged connectors or pins (terminals) refer to the video below.
 
 - 
 
 
  
 Click here to view a video version of this procedure.
 
 
 
 - 
 NOTE: 
 The connector hard-shell information, which is 
measured in millimeters is the distance from the front face of the 
connector to the engagement point on the terminal release tang. Mark the
 listed distance on the terminal removal tool prior to removing the 
terminal.
  NOTE: 
 The dimensions of the connector hard-shell and the 
connector terminals release tang are listed above the corresponding 
graphics.
  
 - 
 
 
 
  
 Audio Front Control Module (ACM), Body Control Module (BCM) and Instrument Panel Cluster (IPC) Electrical Connector 
 
 
 
 
 
 
 
 
 
 | Callout | Connector |  
 | 1 | External terminal release tang |  
 | 2 | Electrical connector locking tab |  
 
 - 
 
 
 
  
 Audio Front Control Module (ACM), Front Controls Interface 
Module (FCIM), Gateway Module A (GWM), and Heating, Ventilation and Air 
Conditioning (HVAC) Control Module Electrical Connector 
 
 
 
 
 
 
 
 
 
 | Callout | Connector |  
 | 1 | Distance to release tang - 
 0.2953
  in (
 7.5
  mm) (inner terminal) - 
 0.4646
  in (
 11.8
  mm) (outer terminal) |  
 | 2 | Terminal width size - 
 0.0244
  in (
 .62
  mm) (inner terminal) - 
 0.1102
  in (
 2.8
  mm) (outer terminal) |  
 
 - 
 
 
 
  
 Body Control Module (BCM) Electrical Connector 
 
 
 
 
 
 
 
 
 
 | Callout | Connector |  
 | 1 | Terminal width size - 
 0.1102
  in (
 2.8
  mm) (inner terminal) - 
 0.2480
  in (
 6.3
  mm) (outer terminal) |  
 | 2 | Distance to release tang - 
 0.1260
  in (
 3.2
  mm) (inner terminal) - 
 0.1575
  in (
 4
  mm) (outer terminal) |  
 | 3 | Terminal width size - 
 0.0591
  in (
 1.5
  mm) |  
 | 4 | Distance to release tang - 
 0.3780
  in (
 9.6
  mm) (lower terminal) |  
 
 - 
 
 
 
  
 Body Control Module (BCM) Electrical Connector 
 
 
 
 
 
 
 
 
 
 | Callout | Connector |  
 | 1 | Terminal width size - 
 0.0591
  in (
 1.5
  mm) (inner terminal) - 
 0.1102
  in (
 2.8
  mm) (outer terminal) |  
 | 2 | Distance to release tang - 
 0.3780
  in (
 9.6
  mm) (inner terminal) |  
 | 3 | Distance to release tang - 
 0.1575
  in (
 4
  mm) |  
 | 4 | Distance to release tang - 
 0.1575
  in (
 4
  mm) |  
 | 5 | Terminal width size - 
 0.2480
  in (
 6.3
  mm) |  
 
 - 
 
 
 
  
 Body Harness In-line Electrical Connector 
 
 
 
 
 
 
 
 
 
 | Callout | Connector |  
 | 1 | Distance to release tang - 
 0.3346
  in (
 8.5
  mm) |  
 | 2 | Terminal width size - 
 0.1102
  in (
 2.8
  mm) |  
 | 3 | Terminal width size - 
 0.0591
  in (
 1.5
  mm) |  
 | 4 | Distance to release tang - 
 0.3858
  in (
 9.8
  mm) (inner) |  
 
 - 
 
 
 
  
 Body Harness In-line Electrical Connector 
 
 
 
 
 
 
 
 
 
 | Callout | Connector |  
 | 1 | Distance to release tang - 
 0.3543
  in (
 9
  mm) |  
 | 2 | Terminal width size - 
 0.0591
  in (
 1.5
  mm) (inner terminal) - 
 0.1102
  in (
 2.8
  mm) (outer terminal) |  
 | 3 | Terminal width size - 
 0.2480
  in (
 6.3
  mm) |  
 | 4 | Distance to release tang - 
 0.3543
  in (
 9
  mm) |  
 
 - 
 
 
 
  
 Body Harness In-line and Seat Harness Electrical Connector 
 
 
 
 
 
 
 
 
 
 | Callout | Connector |  
 | 1 | Distance to release tang - 
 0.4331
  in (
 11
  mm) |  
 | 2 | Terminal width size - 
 0.0591
  in (
 1.5
  mm) |  
 | 3 | Terminal width size - 
 0.0591
  in (
 1.5
  mm) |  
 | 4 | Distance to release tang - 
 0.4331
  in (
 11
  mm) |  
 
 - 
 
 
 
  
 Body Harness In-line and Seat Module Electrical Connector 
 
 
 
 
 
 
 
 
 
 | Callout | Connector |  
 | 1 | Terminal width size - 
 0.0591
  in (
 1.5
  mm) |  
 | 2 | Distance to release tang - 
 0.3937
  in (
 10
  mm) |  
 
    
 WARNING: 
 Never inflate a tire that has been run flat without first 
removing the tire from the wheel to inspect for damage. A damaged tire 
can fail during inflation...
   
 
   Other information:
   Special Tool(s) /
 General Equipment
 
 Flat-Bladed Screwdriver
 
 
 
 Removal
  
 WARNING: 
 The following procedure prescribes critical repair steps 
required for correct restraint system operation during a crash. Follow 
all notes and steps carefully. Failure to follow step instructions may 
result in incorrect operation of the restraint system and increases the 
risk of serious persona..
   
   Removal
 NOTE: 
 Removal steps in this procedure may contain installation details.
 
 
 
 
 
 NOTE: 
 Do not pull the engine appearance cover forward or 
sideways to remove. Failure to press straight upward on the underside of
 the cover at the attachment points may result in damage to the cover or
 engine components.
 
 
 
 
 Remove the engine appearance cover nut.
 
 
 
 
 
 Place your hand unde..