Ford Escape: Body Closures / General Procedures - Power Liftgate Initialization
Programming
NOTE:
This procedure clears and then sets new open and close end points in the RGTM memory.
-
Turn the ignition ON.
-
Using a scan tool perform the RGTM self test to complete power liftgate
initialization. From the diagnostic scan tool, enter TOOLBOX > Self
Test > RGTM > Run Selected Procedure.
Special Tool(s) /
General Equipment
Interior Trim Remover
Inspection
NOTE:
Removal steps in this procedure may contain installation details...
Inspection
NOTE:
Removal steps in this procedure may contain installation details.
NOTE:
LH side shown, RH side similar.
Inspect the body-to-rear door dimensions...
Other information:
Diagnostic Trouble Code (DTC) Chart
Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods (100-00 General Information, Description and Operation).
Module
DTC
Description
Action
GWM
U2100:00
Initial Configuration Not Complete: No Sub Type Information
GO to Pinpoint Test AR
GWM
U3000:44
Cont..
Removal
WARNING:
To prevent the risk of high-voltage shock, always follow
precisely all warnings and service instructions, including instructions
to depower the system. The high-voltage system utilizes approximately
450 volts DC, provided through high-voltage cables to its components and
modules. The high-voltage cables and wiring are identified by orange
harness tape or orange wi..