Ford Escape: Roof Opening Panel / General Procedures - Power Roof Opening Panel Initialization
Initialization
WARNING:
Keep objects and body parts clear of the glass panel when
carrying out the initialization procedure. During the initialization
procedure, the glass panel closes with high force and cannot detect
objects in its path. Failure to follow this instruction may result in
serious personal injury.
NOTE:
The roof opening panel motor must be initialized when
repairs are carried out on the roof opening panel system, including: any
time the roof opening panel motor has been removed, the roof opening
panel glass (fixed panoramic or sliding) has been removed or adjusted,
or if the roof opening panel frame has been removed.
-
With the driver’s door closed, start the engine and then turn the engine off.
-
Open the drivers door.
-
Place the ignition switch in the ignition ON, engine OFF position.
-
NOTE:
This step must be started within 4 seconds from the
time the ignition was placed in the ignition ON, engine OFF position. Do
not release the switch until the glass or shield has completed an
open/close cycle.
-
For sliding glass initialization, press and HOLD
the sliding glass close switch until the glass cycles to the fully
closed position, and then to the fully open position and finally to the
fully closed position. Release the sliding glass closed switch.
-
For shield initialization, press and HOLD the
shield close switch until the shield cycles to the fully closed
position, and then to the fully open position and finally to the fully
closed position. Release the shield close switch.
-
-
Place the ignition switch in the OFF position.
-
Test the system for normal operation. If the roof
opening panel does not operate correctly, repeat the procedure.
Diagnostic Trouble Code (DTC) Chart
Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods (100-00 General Information, Description and Operation)...
Adjustment
Measurement
Measure the roof opening panel movable glass height/flushness.
Measure the roof opening panel sliding glass
front edge-to-header panel height/flushness...
Other information:
What Is Automatic Engine Stop
Automatic engine stop is a feature that
switches the engine off if it has been idling
for an extended period to help you save
fuel.
How Does Automatic Engine Stop Work
Automatic engine stop turns the engine
off. The ignition also turns off in order to
save battery power...
Removal
NOTE:
Removal steps in this procedure may contain installation details.
With the vehicle in NEUTRAL, position it on a hoist.
Refer to: Jacking and Lifting (100-02 Jacking and Lifting - 2.5L Duratec – Hybrid (121kW/164PS) (BG))
...