Special Tool(s) /
General Equipment
Resistance Spotwelding Equipment
Scraper for Straight Edges
Hot Air Gun
8 mm Drill Bit
MIG/MAG Welding Equipment
Spot Weld Drill Bit
Locking Pliers
Materials
Name
Specification
Metal Bonding AdhesiveTA-1, TA-1-B, 3M™ 08115, LORD Fusor® 108B, Henkel Teroson EP 5055
-
Seam SealerTA-2-B, 3M™ 08308, ..
Other information:
Removal
WARNING:
To prevent the risk of high-voltage shock, always follow
precisely all warnings and service instructions, including instructions
to depower the system. The high-voltage system utilizes approximately
450 volts DC, provided through high-voltage cables to its components and
modules. The high-voltage cables and wiring are identified by orange
harness tape or orange wi..
Overview
The RCM continually receives and monitors inputs from the OCSM and various other hard-wired switches and sensors. If the RCM
detects a sudden vehicle deceleration and/or lateral deceleration
based on the information received from the various sensors and
determines that deployment is necessary, it applies voltage and current
to deploy the appropriate SRS components.
The SRS
utilizes..